LED Luminaire Testing Service for Lighting Products

This service provides photometric, electrical safety and functional testing for lamps and luminaires. It supports lighting designers, QA teams and compliance officers preparing regulatory filings and performance claims.

Testing & Calibration Capability Overview

  • Applicable standards: photometry, lumen maintenance, safety and thermal tests aligned to IS/IEC references.
  • Sample types accepted: integrated luminaires, retrofit lamps and modules.
  • Key measures: luminous flux, efficacy, color metrics, temperature rise and electrical safety.
  • Deliverables: photometric files, test reports and safety verification documents.

Engagement Terms & Scheduling

  • Service Format: In-lab photometric measurements and safety testing.
  • Turnaround Time: Typically 5-8 working days for standard photometric and safety batteries.
  • Sample/Equipment Requirement: Submit representative production units with rated power and driver details.
  • Pricing Basis: Priced by photometric scope, sample conditioning and number of parameters.
  • Payment Structure: Standard partial advance with balance on report delivery.

Business Operations: Merchant, Service Provider

Contact us for


By clicking on ‘Send Trade Enquiry’, you agree to our terms & condition and user policies

Where This Service Is Used

Lighting manufacturers and procurement teams use LED luminaire testing to verify photometric performance, safety and thermal behaviour before certification or large-scale deployment. The service supports vendor qualification, performance benchmarking and compliance checks tied to warranty claims.

Results are used to validate energy-efficiency claims and to inform fixture selection for projects requiring documented lumen maintenance and color performance.

How This Service Is Performed

Photometric measurements use an integrating sphere or goniophotometer depending on fixture form factor. Instruments include spectroradiometers, power analyzers and thermal chambers. Tests measure luminous flux, correlated color temperature (CCT), color rendering index (CRI), efficacy and temperature rise under rated conditions.

Electrical safety testing includes insulation, earth continuity and leakage current checks per relevant IS/IEC clauses. Reports include measured values, compliance statements against specified clauses and measurement uncertainty notes.

Documentation & Traceability

  • Accreditation: Methodology and traceability are documented; accreditation details are provided when confirmed in engagement records.
  • Standards/Methods Covered: Photometry and electrical safety reference standards applicable to LED luminaires and lamps.
  • Reporting: Photometric reports, spectral data files, safety test reports and measurement traceability statements.
  • Documents Provided: Test Report, IES/LDT/IESNA photometric files where applicable, Calibration Traceability Statement.

Buyer Decision Guide

Confirm the lab can measure your fixture form factor (integrating sphere vs goniophotometer) and provide spectral data outputs. Verify turnaround options and whether combined photometric+safety bundles are available to reduce iteration risk. A frequent buyer concern is inconsistent measurement method; request the instrumentation list and test protocol references to ensure comparability.

Request a Testing Quote

Share the luminaire type, rated power, quantity and required turnaround to receive a test scope and schedule confirmation.

Frequently Asked Questions

  • How many samples are needed for photometric testing? Typically 1-2 representative production units for photometry; additional samples may be required for lot verification or thermal testing.
  • How is pricing structured for photometric and safety tests? Pricing depends on measurement scope, spectral outputs required and any environmental conditioning; bundled packages are available.
  • Which outputs are provided for lighting projects? Photometric reports, spectral data, IES/IESNA files when measured on a goniophotometer, and safety test reports.
  • What is the expected turnaround? Standard photometric and safety batteries are typically completed in 5-8 working days; combined or extended tests may require more time.
S. No. Testing Product Category Related Standard
1AC/DC Supplied Electronic Control Gear TestingIEC 60929
2Ballasts for Discharge Lamps TestingIS 15882, IEC 60923
3Ballasts for Fluorescent Lamps TestingIS 1534-1, IEC 62442-3
4Compact Fluorescent Lamps TestingANSI C78.5
5Double Capped Retrofit & Conversion Linear Tubular LED Lamps TestingIEC 62776
6Tubular Fluorescent Lamps TestingIS 2418-2
7Double-Capped Fluorescent Lamps TestingANSI C78.81, IEC 60081, IEC 61195
8High Pressure Sodium Vapour Lamps TestingIS 9974-1, IS 9974-2
9Indoor Fluorescent Luminaires TestingIES LM-41-14
10Indoor Luminaries TestingIES LM-46-04
11Lamp Control Gear TestingIEC 61347-2-3, IEC 61347-2-11
12General Purpose Luminaire, Recessed Luminaires, Street Lighting, Portable Luminaires TestingIS 10322-5-1, IS 10322-5-2, IS 10322-5-3, IS 10322-5-4, IS 10322-1, IEC 60598-2-1, IEC 60598-2-2, IEC 60598-2-3, IEC 60598-2-4
13Emergency Lighting TestingIS 10322-5-8, IEC 60598-2-22
14Flood Lights TestingIS 10322-5-5, LM79, IEC 60598-2-5
15Flood Lights, Hand Lamps, Lighting Chains, Emergency Lighting TestingIEC 62301, IS 10322-5-5, IS 10322-1, IS 10322-5-6, IS 10322-5-7, IS 10322-5-8, IEC 60598-2-5, IEC 60598-2-8, IEC 60598-2-20, IEC 60598-2-22, IEC 60598-1, IEC 62087
16Rope Lights TestingIS 10322-5-9 / IEC 60598-2-21
17Self-Ballasted LED Lamps for General Lighting ServicesIS 16102-2, BEE Schedule, EESL Schedule, IEC 62612, LM79
18Self-Ballasted LED Lamps for General Lighting Services, LED Modules for General LightingIS 16102-1, IEC 62560, EESL Schedule, IS 16102-1, IS 16103-1
19Self Ballasted Compact Fluorescent Lamps TestingANSI C78.5
20Self Ballasted Lamps for General Lighting Service CFLIS 15111-1, IEC 60968, IS 15111-2 IEC 60969
21Single-Based Fluorescent Lamps TestingANSI C78.901
22Starters for Fluorescent Lamps TestingIS 2215, IEC 60155
23Lamp Controlgear Ballasts TestingIS 12449-1, IS 15885-2-1, IS 15885-2-3, IS 15885-2-8, IS 15885-2-9, IS 15885-1, IS 15885-2-13, IEC 61347-2-13, IS 10322-1, IEC 61347-2-1, IEC 61347-2-9, IEC 61347-2-3, IEC 61347-2-8, IS 12449-2
24Tubular Fluorescent Lamps TestingIS 12449-2
25Tungsten Filament Lamps for Domestic & Similar General Lighting PurposesIS 15518-1, IEC 60432-1, IS 418